4.9 Test Run ChecklistReview the checklist before performing a test run. Check each item that applies.No. Checklist Page1 Thoroughly read the manual before performing a test run. —2 Turn the power on. 693 Set the voltage for the power supply to E1-01. 94Check the items that correspond to the control mode being used.WARNING! Ensure start/stop and safety circuits are wired properly and in the correct state before energizing the drive. Failure to complycould result in death or serious injury from moving equipment. When programmed for 3-Wire control, a momentary closure on terminal S1may cause the drive to start.No. Checklist Page4 The should illuminate after giving a run command. —5 To give a run command and frequency reference from the LED Digital Operator, press to set to LOCAL.The LO/RE key lights while LOCAL is displayed. 666 If the motor rotates in the opposite direction during the test run, switch two of the drive output terminals (U/T1,V/T2, W/T3). 697 Select the correct duty rating (C6-01) for the application. —8 Set the correct values for the motor rated current (E2-01) and the motor protection selection (L1-01) to ensuremotor thermal protection. —9 If the run command and frequency reference are provided via the control circuit terminals, set the drive forREMOTE and be sure the LO/RE light is out. 6610 If the control circuit terminals should supply the frequency reference, select the correct voltage input signal level(0 to 10 V) or the correct current input signal level (4 to 20 mA or 0 to 20 mA). 6611 Set the proper voltage to terminal A1. (0 to 10 V). 7912 When current input is used, switch the drive built-in DIP switch S1 from the V-side (OFF) to I-side (ON). —13Set the minimum and maximum frequency references to the desired values. Make the following adjustments ifthe drive does not operate as expected:Gain adjustment: Set the maximum voltage/current signal and adjust the analog input gain (H3-03) until thefrequency reference value reaches the desired value.Bias adjustment: Set the minimum voltage/current signal and adjust the analog input bias (H3-04) until thefrequency reference value reaches the desired minimum value.—4.9 Test Run ChecklistYASKAWA ELECTRIC SIEP C710606 31B YASKAWA AC Drive – J1000 Technical Manual 734 Start-Up Programming& Operationhttp://nicontrols.com