9 - 38– +ELECSIGNAL SYSTEM3.If the reverse indicator light fails to come on:CONTINUITY1.Bulb and bulb socket Check the bulb and bulb socket forcontinuity.NO CONTINUITYReplace the bulb and/or bulb socket.CONTINUITY2.Reverse switchRefer to “CHECKING THE SWITCHES”.NO CONTINUITYReplace the reverse switch.3.Voltage Connect the pocket tester (DC 20 V) to thebulb socket coupler.Tester (+) lead → Red/White terminal 1Tester (–) lead → Green/Blue terminal 2MEETSSPECIFICATION Turn the main switch to “ON”. Check the voltage (12 V).Replace the CDI unit.OUT OF SPECIFICATIONThe wiring circuit from the main switch to thebulb socket connector is faulty, repair it.