User Manual UMN:CLIV5812G127To configure an interval of EFM OAMPDUs which are exchanged between local DTE andremote DTE, use the following command.Command Mode Descriptionoam efm interval <1-10> PORTS Global Configures the interval of OAMPDUs. (default: 1second)To configure a lost-link-packet of EFM OAMPDUs which are exchanged between localDTE and remote DTE, use the following command.Command Mode Descriptionoam efm lost-link-packet <5-60>PORTS Global Configures the lost-link-packet counts of OAMPDUs. Itdecides a local_lost_link_timer. (default: 5 )7.2.2 OAM Link MonitoringTo enable/disable the link monitoring function, use the following command.Command Mode Descriptionoam efm link-monitor enable PORTS Global Enables link monitoring function.oam efm link-monitor disable PORTS Disables link monitoring function.To specify an errored window size and threshold according to the event type, use thefollowing command.Command Mode Descriptionoam efm link-monitor framewindow <10-600> threshold <0-65535> PORTSGlobalSpecifies the window size and threshold in case of frameevent.10-600: window size (unit: 100 msec, default:1)0-65535: threshold value (default:1)oam efm link-monitor frame-period window <1000-200000000> threshold <0-65535> PORTSSpecifies the window size and threshold in case offrame-period event.1000-200000000: window size (default: 1000000 frames)0-65535: threshold value (default:10)oam efm link-monitor symbol-period window <1-1000000>threshold <0-65535> PORTSSpecifies the window size and threshold in case ofsymbol-period event.1-1000000: window size (default: 625 million)0-65535: threshold value (default:1)oam efm link-monitor frame-seconds-summary window <10-900> threshold <0-900> PORTSSpecifies the window size and threshold in case offrame-seconds-summary error event.10-900: window size (default: 60 seconds)0-900: threshold value (default:1)