UMN:CLI User ManualV5812G138To configure the first alarm to occur when object is firstly more than threshold or less thanthreshold, use the following command.Command Mode Descriptionstartup-type rising-and-falling RMON Configures the first Alarm to occur when object is firstlymore than threshold or less than threshold.7.4.2.7 Interval of Sample InquiryThe interval of sample inquiry means time interval to compare selected sample data withupper bound of threshold or lower bound of threshold in terns of seconds.To configure interval of sample inquiry for RMON alarm, use the following command.Command Mode Descriptionsample-interval <0-65535> RMON Configures interval of sample inquiry.(unit: second)7.4.2.8 Activating RMON AlarmAfter finishing all configurations, you need to activate RMON alarm. To activate RMONalarm, use the following command.Command Mode Descriptionactive RMON Activates RMON alarm.7.4.2.9 Deleting Configuration of RMON AlarmWhen you need to change a configuration of RMON alarm, you should delete an existingRMON alarm.To delete RMON alarm, use the following command.Command Mode Descriptionno rmon-alarm <1-65535> Global Deletes RMON history of specified number, enter thevalue for deleting.7.4.3 RMON EventRMON event identifies all operations such as RMON alarm in the switch. You canconfigure event or trap message to be sent to SNMP management server when sendingRMON alarm.You need to open RMON Event Configuration mode to configure RMON event.Command Mode Descriptionrmon-event <1-65535> Global Opens RMON Event Configuration mode.1-65535: index number