Electra Elite IPK Document Revision 4Programming Manual 2 - 257______________________________________________________________________________________________________________________________________________________________________1-8-49 New AA-Info Yes/No SelectionGeneral DescriptionUse this Memory Block to specify whether or not New AA-Info is allowed. NewApplication-to-Application (AA) Info is used with internal Voice Mail Systems[i.e.,CMS( )-U( ), FMS( )-U( ), or VMS( )-U( ) ETUs]. For external digital Voice MailSystems and VP/CTI Systems, this Memory Block must be set to NO. Refer to Table2-1 (Voice Mail AA-Info Settings).R2000 or higher is required.DisplaySettingsLK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shadedselection is thedefault.NO YSProgramming Procedures1 Go off-line.2 Press LK1 + LK8 + DI to access the Memory Block.3 Press the corresponding CO/PBX line key to change the setting option.4 Press G to write the selected data and display next Memory Block or Memory Block 1-8-00.5 Press E to go back on-line.System Mode1Submode8Data No.49PC Programming¦+AV4 9 : N E W A A I N F O Y ST I M E D I S P L A YDataNo. SettingDataTitle