7 In-Tank Setup End Factor7-12End FactorIf necessary, press STEP until you see the message:NOTE: This message appears only if you select METER DATA PRESENT: YES.The End Factor allows you to select an end shape type (if known) to improve the AccuChart height-to-volumecalculations. Press CHANGE to view your choices. The default setting of NONE automatically bypasses the EndFactor entry and determines tank profile based upon your selection in the “Tank Profile” entry on page 7-5.Selecting FLAT = an End Factor of 0. Selecting HEMISPHER = an End Factor of 1. Selecting OTHER displaysthe message:If you select NONE, FLAT, or HEMISPHER(E), press ENTER when that choice is visible, then STEP.If you select OTHER, press ENTER and the End Value message appears. Press CHANGE, enter an End Value offrom 0 to 1.0 in 0.1 increments (0.3 is the recommended end value for dished-end tanks), press ENTER, thenSTEP.Calibration UpdateIf necessary, press STEP until you see the message:Note: This message appears only if you select METER DATA PRESENT: YES. Note for international installations,CAL UPDATE will be PERIODIC if HRM is enabled (see “TLS-350 Consoles” on page 4-1).IMPORTANT! For proper setup and operation of this feature, you should:1. Pressure-test all lines for tightness prior to startup.2. Calibrate all dispensing meters “on strike” or within one cubic inch per five gallons (8.65 centilitres per 10 litres[0.865%]).3. Run all tanks over as wide a range of fuel levels as possible for the first 56 days of operation to improvecalibration accuracy.When this feature is enabled, you can control when AccuChart updates the calibration chart. The product volumeof your tank may be recalculated when AccuChart updates the calibration chart. If you are performing manualreconciliation, you will probably want to control when AccuChart changes the product volume of your tank.AccuChart FeaturesAccuChart is permitted in line, siphon, or a combination of line and siphon manifolded tanks with the followingrestrictions:• A siphon manifolded set can have no more than 2 tanks.• There can be no more than 4 sets of siphon manifolded tanks per system.• AccuChart does not work on manifolded tanks with a BDIM.T1: (Product Label)END FACTOR: NONET1: (Product Label)END VALUE: X.XT1: (Product Label)CAL UPDATE: IMMEDIATE