7-17 In-Tank SetupThe In-Tank Setup function allows you to enter information about your tanks and the products they contain. Also,through this function you set up the monitoring, reporting, and alarm features for each tank.You must enter data individually for each connected tank.Selecting the In-Tank Setup FunctionTo select In-Tank Setup, press FUNCTION until you see the message:Press STEP to continue.Tank ConfigurationIf necessary, press STEP until you see the message:Use the message shown above to tell the system which of the four probe positions on a module are connected toprobes.HOW THE SYSTEM CONFIGURES IN-TANK PROBESIf in-tank probes are installed, the system recognizes the presence and module slot location(s) of Probe InterfaceModule(s). It also establishes a module number based on slot location. For example, if modules are installed inslots #3 and #4, the module in slot #3 automatically becomes module #1 and the module in slot #4 becomesmodule #2.As you specify which positions on a module are connected to probes, the system establishes a number for eachprobe that corresponds to the probe’s position on the module. For example, if there is a probe connected topositions 2 and 3 of module 1, the probe for position 2 becomes T2 and the probe for position 3 becomes T3.To indicate that a probe position on the module is connected to a probe, choose the number corresponding to thatposition. For example, if the position is 3, choose 3 for the position. To indicate that a position is not connected toa probe, choose X for that position.SPECIFYING IN-TANK PROBE POSITIONSTo specify whether position 1 is connected, press CHANGE until the correct choice appears (1 if the position isconnected, X if it is not). Press the Right Arrow key to move to position 2 and press CHANGE again until thecorrect choice appears. Repeat these steps until you have correctly specified all four probe positions. When youhave entered a choice for all positions, press ENTER to confirm your entry. The system displays the followingmessage:IN-TANK SETUPPRESS TO CONTINUETANK CONFIG - MODULE 1SLOT #: X X X XSLOT # - 1 2 3 4PRESS TO CONTINUE