Configuring VPIM Parameters 79Configuring VPIMParametersUsing the NBX NetSet utility, you can configure several VPIM controlparameters, check the status of the VPIM queues, and obtain statistics onrecent VPIM activity.VPIM ControlParametersTo set the VPIM control parameters:1 In the NBX NetSet - Main Menu window, click NBX Messaging.2 Click the VPIM tab. Table 16 describes the fields.OperationsManagementTo manage outgoing voice mail messages, click Queue Management. TheOperations Management dialog box appears. See Table 17.Table 16 VPIM Tab FieldsField PurposeMax message size Controls the size of incoming messages from othersites. If a message is larger than the specifiedvalue, the NBX system rejects it. The default valuerepresents a voice mail message approximately 4to 5 minutes in length.Default: 3000 KilobytesTime between send attempts(minutes)For outgoing messages, the NBX system may notbe able to contact the target system on the firstattempt. If so, the NBX system attempts to contactthe target system later. To change the timebetween attempts, change this number.Default: 15 minutesMinimum: 1 minuteMaximum: 60 minutesMax number of send attempts Specifies the number of times (Default: 4) that theNBX system tries to connect to the target system.After the specified number of send attempts, themessage is returned to the sender’s voice mailboxwith a notice that the message could not be sent.Table 17 Operations Management Dialog Box FieldsField PurposeOperations status The status of the queue of outgoing voice mail messages.Possible values: Starting, Ready, Processing, Stopped.