2.2.13 Changing a Data ValueIf the selected parameter shows a numeric data value,change the selected data value with the [◀] [▶] navigationkeys and the [▲] [▼] navigation keys. Press [◀] [▶] keys tomove the cursor horizontally.130BP069.101- 6*113 RPM 1.78 A 1(1)Load depen. setting1 - 60 Low speed loadcompensation100%Illustration 2.18 Changing a Data ValuePress the [▲] [▼] keys to change the data value. [▲]increases the data value, and [▼] decreases the data value.Place the cursor on the value to save and press [OK].130BP070.101 - 60 Low speed loadcompensation1 0%Load depen. setting 1- 6*729RPM 6.21A 1(1)6Illustration 2.19 Saving a Data Value2.2.14 Infinitely Variable Change ofNumeric Data ValueIf the selected parameter shows a numeric data value,select a digit with [◀] [▶].130BP073.10635 RPM1 - 71 Start Delay00.0s0.44 A 1 (1)1- 7*Start AdjustmentsIllustration 2.20 Selecting a DigitChange the selected digit infinitely variably with [▲] [▼].The cursor indicates the selected digit. Place the cursor onthe digit to save and press [OK].130BP072.10957RPM1-71 High starting torque time0. s11.58A 1 (1)1-7*Start Adjustments4Illustration 2.21 Saving2.2.15 Value, Step by StepCertain parameters can be changed step by step. Thisapplies to:• Parameter 1-20 Motor Power [kW].• Parameter 1-22 Motor Voltage.• Parameter 1-23 Motor Frequency.The parameters are changed both as a group of numericdata values and as numeric data values that are infinitelyvarying.2.2.16 Readout and Programming ofIndexed ParametersParameters are indexed when placed in a rolling stack.Parameter 15-30 Fault Log: Error Code toparameter 15-32 Alarm Log: Time contain a fault log, whichcan be read out. Select a parameter, press [OK], and pressthe [▲] [▼] keys to scroll through the value log.For example, parameter 3-10 Preset Reference is changed asfollows:1. Select the parameter, press [OK], and press [▲] [▼]to scroll through the indexed values.2. To change the parameter value, select theindexed value and press [OK].3. Change the value by pressing [▲] [▼].4. Press [OK] to accept the new setting.5. Press [Cancel] to abort. Press [Back] to leave theparameter.2.2.17 How to Program on the NumericalLocal Control PanelThe following instructions are valid for the numerical LCP(LCP 101).The control panel is divided into 4 functional groups:• Numerical display.• Menu keys and indicator lights - changingparameters and switching between displayfunctions.• Navigation keys and indicator lights.• Operation keys and indicator lights.How to Program VLT® AQUA Drive FC 20222 Danfoss A/S © 05/2018 All rights reserved. MG20OB0222