193⿎ Condition setting of GS1 DataBar1234 56 7891011Description1 Type :Specifies the type of GS1 DataBar.• When the code type is GS1 DataBar, Standard & Truncated, Stacked, or Stacked Omnidirectional areavailable.• When the code type is GS1 DataBar Limited, only Limited is available.• When the code type is GS1 DataBar Expanded, Expanded or Expanded Stacked are available.Reference• When GS1 DataBar Limited is used, select how to specify the guard pattern width in “Bar Code Setting” (P.257) inEnvironment setting.2 Module width (W) :Specifies the minimum width of bar or space. Set the larger value than “Line Width” set in laser setting screen.Setting Range 0.050 to 1.000 mm3 Bar Code Height *1 :Lower Bar Code Height *2 :One Bar Code Height *3 :Specifies the height of bar code / lower bar code / respective tiers on a multi-tiered bar code.GS1 DataBar Standard&Truncated, GS1 DataBar Limited, or GS1 DataBar Expanded onlyGS1 DataBar Stacked onlyGS1 DataBar Expanded Stacked or GS1 DataBar Stacked Omnidirectional onlySetting Range1.000 to 90.000 mm (LP-V10)1.000 to 110.000 mm (LP-430 / LP-420 / LP-410)1.000 to 160.000 mm (LP-435 / LP-425 / LP-V15)1.000 to 55.000 mm (LP-431 / LP-421 / LP-411 / LP-W052)4 Invert :To invert the marking lines of the code symbol, check the box.With inversion setting bars are not marked, but spaces in the code symbol are marked by laser.ME-LP400V-OP-6