592-1 Installation2-1-1 Installation EnvironmentUse this product in the following environments.Item Installation environment conditionsOperating Ambient Temperature *1 0°C to +40°COperating Ambient Humidity *1 35 to 85%RHAmbient Temperature for Storage *1 -10°C to +60°C *2Use location Indoor; at an altitude of 1000 m or below*1 : No condensation or freezing shall be allowed.*2 : If there is a gap between the stored temperature and operating temperature, make sure to have the product get usedto the operating ambient temperature gradually prior to use to prevent the dew condensation.Notice• Do not install the laser marker at a place where vibrations and shocks can be directly transmitted to it.• Do not incorporate the laser marker in a unit where the laser head will be moved. It may cause failure.• Do not use the laser marker at a place with a lot of oil mist and/or dust. Take measures to prevent oil contents and dustfrom entering into the laser marker, e.g. using a storage box.⿎ Installation environment for the stable operationFor the stable operation, install the laser marker with an appropriate protection measures as follows according to the usageenvironment.• Protection in a dusty placeIf the laser marker is installed at a dusty and/or oil-mist-laden place, it could cause malfunction of the product. Take ameasures to protect the laser marker from penetration of the contamination, such as placing the head and the controllerin the dust and/or oil protective enclosure.Besides, clean or replace the filters regularly in accordance with the usage conditions.Example of a storage box:According to the ambient temperature, use a storage box equipped with panel cooler or heat exchanger to maintain theair-cooling performance of the laser marker.Panel CoolerorHeat ExchangerWARNING • If the laser emission indicator on the laser marker is placed out of the sight ofoperators, place the external indicator light or warning lamp on the immediatelyapparent place on the system.ME-LP400V-OP-6