266Laser Power CorrectionAfter the power check if the power decays lower than the delivery status, correct the laser power setting value.Select the correction mode from “Auto” or “Manual”.• Auto: Sets the power correction ratio with the auto-calculated value so as to set the power to the power output atshipping.• Manual: Corrects the power setting with the given value [%].WARNING • Laser is radiated with the internal shutter closed. Be sure to use the protectivegoggle and enclosure in case of laser leakage. Also, do not place any objectsaround the radiating area.1. Press [POWER CHECK].2. The Confirm screen is displayed.Press [START].The current laser marker power is measured.3. The Power Monitor screen is displayed.For the auto correction, Press “Auto”.For the manual correction, press “Manual” and inputpower correction value, then press [SET].Setting range: 50 to 200[%]4. Press [START].The correction ratio after power correction and correction date areupdated.ME-LP400V-OP-6