305ERRORCODE Error details MeasuresE606 Existed marking data outside of marking area.Contain marking data within marking area.• Change marking position.• Make characters smaller.• Narrow character interval.* If there is no data out of the marking field in theimage display, check the “system offset” in theenvironment setting.“System offset” value is not shown in the imagedisplay.E607 Cannot create bolded character.• Set any standard font without original 4 font.• Use Font Maker provided to create the properpattern font.• Set line width of bold character to quarter or belowof character height and width.• When marking the bold character, set thecomparison ratio between character height andwidth become 1/4 to 4.• Check the line width of bold character not exceedthe specified value.E610E612Lack of marking memory.• Marking data is too large.• The line length is too long. (spiral, etc.)• Reduce numbers of characters and logo data.• Reduce numbers of step & repeat.• Reduce numbers of a start point and a end pointof characters or logo data.• Separate the long segment into short data.E620E621Flying object area over.(Can not follow line speed of flying object marking.)• Shorten marking time with the following methods.• Speed up scan speed.• Narrow character interval.• Make characters smaller.• Reduce numbers of characters.• Change setting of curve/edge.• Reduce numbers of character lines.• Displace a start point of marking, etc.• Adjust the line speed of the flying object.• Adjust the waiting time of the flying object.• Set the coordinate of the marking data close to thecenter of the marking field.E622 Flying object time over.(Can not follow line speed of flying object marking.)E623 Too narrow marking interval for proportioned flyingobject.Increase setting value of marking spacing. Shortenmarking time with the following methods.• Speed up scan speed.• Narrow character interval.• Make characters smaller.• Reduce numbers of characters.• Change setting of curve/edge.• Reduce numbers of character lines.• Set smaller value to the one-shot output time, etc.E630 Too much quantity of Step and Repeat marking. Reduce numbers of characters to be marked. (Max.:1000)ME-LP400V-OP-6