Diagnostics & Troubleshooting 6 - 20TroubleshootingDue to parameter setting errors, faulty wiring, etc., the Drive and motor may not operate as expected when the system isstarted. If this occurs, use this section as a reference and apply the appropriate measures.If a fault or alarm is displayed on the Digital Operator, refer to Table 6.1 and Table 6.2. If A Parameter Cannot Be SetUse the following information if a Drive parameter cannot be set. The display does not change when the INCREASE and DECREASE keys are pressed.The following causes are possible:The Drive is operating (Drive mode).There are some parameters that cannot be set during operation. Remove the run command and then set the parameter.Parameter write enable is input.This occurs when "parameter write enable" (set value: 1B) is set for a multi-function digital input terminal (H1-01 to H1-06).If the terminal is open, the Drive parameters cannot be changed. Close the terminal and then set the parameters.Passwords do not match (Only when a password is set.)If the parameter A1-04 (Password) and A1-05 (Password Setting) settings are different, the parameters for the initialize modecannot be changed. Enter the correct password in A1-04.If you cannot remember the password, display A1-05 (Password Setting) by pressing the Shift/Reset Key and the MENU Keysimultaneously while in the A1-04 display. Reset the password and input the reset password in parameter A1-04. OPE01 through OPE11 is displayed.The set value for the parameter is wrong. Refer to Table 6.3 OPE Error Displays in this chapter and correct the setting. CPF00 or CPF01 is displayed.This is a Digital Operator communication error. The connection between the Digital Operator and the Drive may be faulty.Remove the Digital Operator and then re-install it.