3.6 Keypad Operation130 YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual5. Press or to select [C1 Accel & Decel Time], and press .6. Press or to select C1-01, and press .7. Press or to select a specific digit. Press or select the desired number.• Press [Default] to reset the parameters to the factory default.• Press [Min/Max] will alternate between the minimum value and maximum value.8. Press to confirm changes.9. Continue to set parameters or press (Back) to return to the HOME screen.This completes the parameter changes.◆ Checking Commonly Used ParametersDisplays the parameter set in A2-01 to A2-32 [User Parameter 1 to User Parameter 32]. In addition, not only is itpossible to check the parameters that have been set, but further changes in their setting values can be made aswell.Note:Always displays A1-06 [Application Selection] at the top of the list. The settings for A2-01 to A2-32 vary depending on the valueselected for A1-06 making it easy to set and reference the required parameter settings.1. Press (Home) to display the HOME screen.Note:• [Home] appears in the upper right hand corner of the screen when in HOME mode.• If [Home] is not displayed for , press (Back), and then press to display [Home].