Parameter List1010.21 Defaults by Drive Model and Duty Rating ND/HDYASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual 531No. *1 Name Unit Default setting- DriveModel - 4002 4004 4005 4007C6-01Normal /HeavyDutySelection-HD1 ND1 HD1 ND1 HD1 ND1 HD1 ND10 1 0 1 0 1 0 1o2-04DriveModelSelectionHex. 92 93 94 95E2-11(E4-11)MotorRatedPower(kW)kW 0.55 0.75 1.1 1.5 1.5 2.2 2.2 3.0L2-03Momentary PowerLoss MinBB Times 0.2 0.3 0.3 0.4 0.4 0.5 0.5 0.5L2-04MomentPowLossVolRecoveryRampTimes 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3L2-05Undervoltage DetectLevel(Uv1)- 380 380 380 380 380 380 380 380L3-24MotorAccelTime forInertia Cals 0.178 0.142 0.142 0.166 0.166 0.145 0.145 0.145L8-02OverheatAlarmLevel °C 110 110 110 110 112 112 110 110L8-09OutputGroundFaultDetectSelect- 1 1 1 1 1 1 1 1L8-35 InstallationMethodSelection- 2 2 2 2 2 2 2 2L8-38CarrierFrequencyReduction- 2 2 2 2 2 2 2 2n1-03HuntingPreventionTimeConstantms 10 10 10 10 10 10 10 10n5-02MotorAcceleration Time s 0.178 0.142 0.142 0.166 0.166 0.145 0.145 0.145*1 Parameters within parentheses are for motor 2.