10.21 Defaults by Drive Model and Duty Rating ND/HD524 YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical ManualNo. *1 Name Unit Default setting- DriveModel - 2042 2056 2070 2082C6-01Normal /HeavyDutySelection-HD ND HD ND HD ND HD ND0 1 0 1 0 1 0 1o2-04DriveModelSelectionHex. 6B 6D 6E 6FE2-11(E4-11)MotorRatedPower(kW)kW 7.5 11 11 15 15 18.5 18.5 22b3-06SpeedEstimationCurrentLevel 1- 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5b3-08SpeedSearchACR Gain- 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5b3-26DirectionDetermining Level 1000 1000 1000 1000 1000 1000 1000 1000 1000b8-03EnergySavingFilter Times 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50b8-04EnergySavingCoefficientValue- 72.69 70.44 70.44 63.13 63.13 57.87 57.87 51.79C5-17(C5-37)MotorInertia kgm 2 0.037 0.053 0.053 0.076 0.076 0.138 0.138 0.165C6-02CarrierFrequencySelection- 1 7 1 7 1 7 1 7E2-01 (E4-01)MotorRatedCurrentA 26.6 39.7 39.7 53 53 65.8 65.8 77.2E2-02 (E4-02)MotorRated Slip Hz 1.3 1.7 1.7 1.6 1.6 1.67 1.67 1.7E2-03 (E4-03)Motor No-LoadCurrent A 8 11.2 11.2 15.2 15.2 15.7 15.7 18.5E2-05 (E4-05)MotorLine-to-LineResistanceΩ 0.288 0.23 0.23 0.138 0.138 0.101 0.101 0.079E2-06 (E4-06)MotorLeakageInductance% 15.5 19.5 19.5 17.2 17.2 15.7 20.1 19.5E2-10 (E4-10)Motor IronLoss W 262 245 245 272 272 505 505 538E5-01PM MotorCodeSelection- 120B 120B 120D 120D 120E 120E 120F 120FL2-02MomentaryPowerLossRide-Thru Times 1 1 2 2 2 2 2 2L2-03Momentary PowerLoss MinBB Times 0.8 0.9 0.9 1 1 1 1 1