10.9 F: Options434 YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manualâ—† F5: Digital Output OptionNo.(Hex.) Name Description Default(Range) Ref.F5-01(0399)Terminal P1-PCOutput Selection The function output from terminal P1-PC on the DO-A3 card isselected by the MFDO setting value. This parameter is enabledwhen F5-09 = 2 [DO-A3 Output Mode Selection = 8 channel select(F5-01 to F5-08)].0(0 - 1A7)729F5-02(039A)Terminal P2-PCOutput Selection The function output from terminal P2-PC on the DO-A3 card isselected by the MFDO setting value. This parameter is enabledwhen F5-09 = 2 [DO-A3 Output Mode Selection = 8 channel select(F5-01 to F5-08)].1(0 - 1A7)729F5-03(039B)Terminal P3-PCOutput Selection The function output from terminal P3-PC on the DO-A3 card isselected by the MFDO setting value. This parameter is enabledwhen F5-09 = 2 [DO-A3 Output Mode Selection = 8 channel select(F5-01 to F5-08)].2(0 - 1A7)729F5-04(039C)Terminal P4-PCOutput Selection The function output from terminal P4-PC on the DO-A3 card isselected by the MFDO setting value. This parameter is enabledwhen F5-09 = 2 [DO-A3 Output Mode Selection = 8 channel select(F5-01 to F5-08)].4(0 - 1A7)729F5-05(039D)Terminal P5-PCOutput Selection The function output from terminal P5-PC on the DO-A3 card isselected by the MFDO setting value. This parameter is enabledwhen F5-09 = 2 [DO-A3 Output Mode Selection = 8 channel select(F5-01 to F5-08)].6(0 - 1A7)730F5-06(039E)Terminal P6-PCOutput Selection The function output from terminal P6-PC on the DO-A3 card isselected by the MFDO setting value. This parameter is enabledwhen F5-09 = 2 [DO-A3 Output Mode Selection = 8 channel select(F5-01 to F5-08)].37(0 - 1A7)730F5-07(039F)Terminal M1-M2Output Selection Selects the function output from terminal M3-M2 on the DO-A3card by the setting value for the multi-function digital output. Thisparameter is enabled when F5-09 = 2 [DO-A3 Output ModeSelection = 8 channel select(F5-01 to F5-08)].F(0 - 1A7)730F5-08(03A0)Terminal M3-M4Output Selection Selects the function output from terminal M3-M4 on the DO-A3card by the setting value for the multi-function digital output. Thisparameter is enabled when F5-09 = 2 [DO-A3 Output ModeSelection = 8 channel select(F5-01 to F5-08)].F(0 - 1A7)730F5-09(03A1)DO-A3 OutputMode Selection Selects the output mode of signals output from the DO-A3 card.0 : 8 channel individual1 : Binary code output2 : 8 channel select(F5-01 to F5-08)0(0 - 2)730V/f CL-V/f OLV CLV AOLV OLV/PMOLV/PM AOLV/PM CLV/PM EZOLVV/f CL-V/f OLV CLV AOLV OLV/PMOLV/PM AOLV/PM CLV/PM EZOLVV/f CL-V/f OLV CLV AOLV OLV/PMOLV/PM AOLV/PM CLV/PM EZOLVV/f CL-V/f OLV CLV AOLV OLV/PMOLV/PM AOLV/PM CLV/PM EZOLVV/f CL-V/f OLV CLV AOLV OLV/PMOLV/PM AOLV/PM CLV/PM EZOLVV/f CL-V/f OLV CLV AOLV OLV/PMOLV/PM AOLV/PM CLV/PM EZOLVV/f CL-V/f OLV CLV AOLV OLV/PMOLV/PM AOLV/PM CLV/PM EZOLVV/f CL-V/f OLV CLV AOLV OLV/PMOLV/PM AOLV/PM CLV/PM EZOLVV/f CL-V/f OLV CLV AOLV OLV/PMOLV/PM AOLV/PM CLV/PM EZOLV