Parameter List1010.18 A1-02 [Motor 1 Control Mode] Dependent ParametersYASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual 515No. Name SettingRange UnitControl Method (Value set in A1-02)OLV/PM(5)AOLV/PM(6)CLV/PM(7)EZOLV(8)d3-04 Jump FrequencyWidth 0.0 to 20.0 *2 0.1 1.0 Hz 1.0 % 1.0 % 1.0 %d5-02 Torque ReferenceDelay Time 0 to 1000 1 ms - - 0 -E1-04 Maximum OutputFrequency 40.0 to 400.0 *3 0.1 Hz Determined byE5-01Determined byE5-01Determined byE5-01 -E1-05 Maximum OutputVoltage 0.0 to 255.0 *4 0.1 V Determined byE5-01Determined byE5-01Determined byE5-01 -E1-06 Base Frequency 0.0 to 400.0 0.1 Hz Determined byE5-01Determined byE5-01Determined byE5-01 -E1-07 Mid Point AFrequency 0.0 to 400.0 0.1 Hz - - - -E1-08 Mid Point AVoltage 0.0 to 255.0 *4 0.1 V - - - -E1-09 Minimum OutputFrequency 0.0 to 400.0 0.1 Hz Determined byE5-01Determined byE5-01 0.0 -E1-10 Minimum OutputVoltage 0.0 to 255.0 *4 0.1 V - - - -F1-01 Encoder 1 PulseCount (PPR) 0 to 60000 1 ppr 1024 1024 1024 600F1-05 Encoder 1RotationSelection0 to 1 1 1 1 1 0F1-09OverspeedDetection DelayTime0.0 to 2.0 0.1 s - - 0.0 -H4-20 Output powermonitor level 0.00 to 650.00 0.01 Determined byE5-01Determined byE5-01Determined byE5-01Determined byE9-07L1-01 Motor OverloadProtection Select 0 to 4 1 4 4 5 Determined byE9-01L3-20 DC Bus VoltageAlignment Gain 0.00 to 5.00 0.01 0.65 0.65 0.65 0.65L3-21 Deceleration RateCalculation Gain 0.10 to 10.00 0.01 1.00 1.00 1.00 1.00L3-36 VibraSuppressionGain duringAccel 0.0 to 100.0 0.1 - - - -L4-01 Speed AgreeDetection Level 0.0 to 400.0 *1 0.1 0.0 Hz 0.0 % 0.0 % 0.0 %L4-02 Speed AgreeDetection Width 0.0 to 20.0 *2 0.1 2.0 Hz 4.0% 4.0% 4.0%L4-03Speed AgreeDetection Level(Positive /Negative)-400.0 to 400.0*5 0.1 0.0 Hz 0.0 % 0.0 % 0.0 %L4-04Speed AgreeDetection Width(Positive /Negative SideDetection)0.0 to 20.0 *2 0.1 2.0 Hz 4.0% 4.0% 4.0%L8-38 Carrier FrequencyReduction 0 to 2 1 0 0 0 0L8-40Carrier FrequencyReduction OffDelay Time0.00 to 2.00 0.01 s 0.00 0.00 0.00 0.00