10.21 Defaults by Drive Model and Duty Rating ND/HD528 YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical ManualNo. *1 Name Unit Default setting- DriveModel - 2257 2313 2360 2415C6-01Normal /HeavyDutySelection-HD ND HD ND HD ND HD ND0 1 0 1 0 1 0 1o2-04DriveModelSelectionHex. 75 76 77 78E2-11(E4-11)MotorRatedPower(kW)kW 55 75 75 90 90 110 110 110b3-06SpeedEstimationCurrentLevel 1- 0.5 0.7 0.7 0.7 0.7 0.7 0.7 0.7b3-08SpeedSearchACR Gain- 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5b3-26DirectionDetermining Level - 1000 1000 1000 1000 1000 1000 1000 1000b8-03EnergySavingFilter Times 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00b8-04EnergySavingCoefficientValue- 31.35 23.1 23.1 20.65 20.65 18.12 18.12 18.12C5-17(C5-37)MotorInertia kgm 2 0.49 0.90 0.90 1.10 1.10 1.90 1.90 1.90C6-02CarrierFrequencySelection- 1 7 1 7 1 7 1 7E2-01 (E4-01)MotorRatedCurrentA 190 260 260 260 260 260 260 260E2-02 (E4-02)MotorRated Slip Hz 1.43 1.39 1.39 1.39 1.39 1.39 1.39 1.39E2-03 (E4-03)Motor No-LoadCurrent A 45.6 72 72 72 72 72 72 72E2-05 (E4-05)MotorLine-to-LineResistanceΩ 0.022 0.023 0.023 0.023 0.023 0.023 0.023 0.023E2-06 (E4-06)MotorLeakageInductance% 20.5 20 20 20 20 20 20 20E2-10 (E4-10)Motor IronLoss W 960 1200 1200 1200 1200 1200 1200 1200E5-01PM MotorCodeSelection- 1215 1215 1216 1216 FFFF FFFF FFFF FFFFL2-02MomentaryPowerLossRide-Thru Times 2 2 2 2 2 2 2 2L2-03Momentary PowerLoss MinBB Times 1.3 1.5 1.5 1.5 1.5 1.7 1.7 1.7