10.21 Defaults by Drive Model and Duty Rating ND/HD536 YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical ManualNo. *1 Name Unit Default setting- DriveModel - 4075 4089 4103 4140C6-01Normal /HeavyDutySelection-HD1 ND1 HD1 ND1 HD1 ND1 HD1 ND10 1 0 1 0 1 0 1o2-04DriveModelSelectionHex. A1 A2 A3 A4E2-11(E4-11)MotorRatedPower(kW)kW 30 37 37 45 45 55 55 75b3-06SpeedEstimationCurrentLevel 1- 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.7b3-08SpeedSearchACR Gain- 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.8b3-26DirectionDetermining Level - 1000 1000 1000 1000 1000 1000 1000 1000b8-03EnergySavingFilter Times 0.50 0.50 0.50 0.50 0.50 2.00 2.00 2.00b8-04EnergySavingCoefficientValue- 92.54 76.32 76.32 71.56 71.56 67.2 67.2 46.2C5-17(C5-37)MotorInertia kgm 2 0.220 0.273 0.273 0.333 0.333 0.490 0.49 0.90C6-02CarrierFrequencySelection- 1 7 1 7 1 7 1 7E2-01(E4-01)MotorRatedCurrentA 52.3 65.6 65.6 79.7 79.7 95 95 130E2-02(E4-02)MotorRated Slip Hz 1.8 1.33 1.33 1.6 1.6 1.46 1.46 1.39E2-03(E4-03)Motor No-LoadCurrent A 10.9 19.1 19.1 22 22 24 24 36E2-05(E4-05)MotorLine-to-LineResistanceΩ 0.269 0.155 0.155 0.122 0.122 0.088 0.088 0.092E2-06(E4-06)MotorLeakageInductance% 20.7 18.8 18.8 19.9 19.9 20 20 20E2-10(E4-10)Motor IronLoss W 750 925 925 1125 1125 1260 1260 1600E5-01PM MotorCodeSelection- 1242 1242 1243 1243 1244 1244 1245 1245L2-02MomentaryPowerLossRide-Thru Times 2 2 2 2 2 2 2 2L2-03Momentary PowerLoss MinBB Times 1.1 1.1 1.1 1.2 1.2 1.2 1.2 1.3