Link Layer Protocolundo fr x25 templateViewDLCI viewParametername: Name of X25 template.DescriptionUsing the fr x25 template command, you can configure the X.25 attributes for X.25over frame-relay via associating an X.25 template to the DLCI in T1.617 AnnexG mode.Using the undo fr x25 template command, you can disable the X.25 template andrestore the initial X.25 attributes.Frame Relay network does not provide reliable transmission. To ensure reliabletransmission, call signals are transmitted on an X.25 VC, as the messageacknowledgement mechanism of X.25 can guarantee reliable transmission. Thiscommand is used to configure the X.25 attributes.For related commands, see x25 template.Example# Specify DLCI 100 to use X.25 template vofr.[3Com-fr-dlci-100]fr x25 template vofr5.1.12 lapb max-frameSyntaxlapb max-frame n1-valueundo lapb max-frameViewInterface viewParametern1-value: the N1 parameter, ranging 1056 bits to 12804 bits. By default, the n1-value is12032 bits.DescriptionUsing the lapb max-frame command, you can configure the LAPB N1parameter.Using the undo lapb max-frame command, you can restore to the default N1 value.The N1 value is the maximum number of bits of I frame that the DCE or DTE deviceexpects to receive from the remote device. This value should be 8 times the MTU plus51