Example of Viewing sFlow Configuration (Global)The first bold line indicates sFlow is globally enabled.The second bold lines indicate sFlow is enabled on Te 1/16 and Te 1/17Dell#show sflowsFlow services are enabledGlobal default sampling rate: 32768Global default counter polling interval: 201 collectors configuredCollector IP addr: 133.33.33.53, Agent IP addr: 133.33.33.116, UDP port: 634377 UDP packets exported0 UDP packets dropped165 sFlow samples collected69 sFlow samples dropped due to sub-samplingStack-unit 1 Port set 0 H/W sampling rate 8192Te 1/16: configured rate 8192, actual rate 8192, sub-sampling rate 1Te 1/17: configured rate 16384, actual rate 16384, sub-sampling rate 2Displaying Show sFlow on an InterfaceTo view sFlow information on a specific interface, use the following command.• Display sFlow configuration information and statistics on a specific interface.EXEC modeshow sflow interface interface-nameExamples of the sFlow show CommandsThe following example shows the show sflow interface command.Dell#show sflow interface tengigabitethernet 1/1Te 1/1sFlow type :IngressConfigured sampling rate :16384Actual sampling rate :16384Counter polling interval :20Extended max header size :128Samples rcvd from h/w :0The following example shows the show running-config interface command.Dell#show running-config interface tengigabitethernet 1/16!interface TenGigabitEthernet 1/16no ip addressswitchportsflow ingress-enablesflow sample-rate 8192no shutdownDisplaying Show sFlow on a Stack-unitTo view sFlow statistics on a specified Stack-unit, use the following command.• Display sFlow configuration information and statistics on the specified interface.EXEC modeshow sflow stack—unit slot-number856 sFlow