SCS Buffer ControlThis option is used in Coax LU1/SCS mode only.v Don’t Wait (the default). The printer does not wait for the job to be printedbefore sending the print completion to the host.v Wait Until Done. The printer waits for the job to print before sending the printcompletion to the host.This option speeds up the LU1 job printing for short jobs. If you select “Don’tWait”, there is a risk that you may not be able to recover the print job when theprinter has fault.Cancel BuffersCANCEL BUFFERS has the following options:v Enable (the default). Cancels all buffers when a job is put on hold from the hostor when the Cancel key is pressed.v Disable. Clears the coax internal buffer, not the print engine buffers, when a jobis put on hold from the host or when the Cancel key is pressed.Hex Transparent ControlYou can enable additional features that are not available in standard IBMemulations. To access these features, send lead-in character text commands in thedata stream. You can also use ASCII codes X'80' through X'9F' as control codes ifconfigured to do so.Lead-In CharactersThe Lead-In Character commands must have a start and end code. Set 1 is thefactory default. Three sets (each containing a start and end code) are available:v Set 1: start code = <%end code = >v Set 2: start code = ¬¬end code = $v Set 3: start code = _%end code = _v User DefinedUser Defined Codesv Start Code 2: X'5F'* (the default)v Start Code 1: X'5F'v Stop code: X'5B'The codes can be set to X'40' - X'FF' rangeChapter 4. The Configuration Menus 81