Parker HannifinP Series User Guide 2751 Trigger by index pulse signal3 – Reserved4 0 Do not capture positive edge position value of touch probe 11 Capture positive edge position value of touch probe 15 0 Do not capture negative edge position value of touch probe 11 Capture negative edge position value of touch probe 16 to 7 – Reserved8 0 Do not use touch probe 21 Use touch probe 29 0 Single trigger mode1 Continuous trigger mode10 0 Trigger by touch probe 2 input1 Trigger by index pulse signal11 – Reserved12 0 Do not capture positive edge position value of touch probe 21 Capture positive edge position value of touch probe 213 0 Do not capture negative edge position value of touch probe 21 Capture negative edge position value of touch probe 214 to 15 – ReservedTable 108. Touch Probe Functions0x60B9 Touch Probe Status ALLVariableFormatSetting Range DefaultValue Unit AccessibilityPDOAllocationChangePropertyStoreUINT - - - RO Yes - NoShow touch probe status.Bit Value Descriptions0 0 Do not use touch probe 11 Use touch probe 11 0 Positive edge position value of touch probe 1 is not stored1 Positive edge position value of touch probe 1 is stored2 0 Negative edge position value of touch probe 1 is not stored1 Negative edge position value of touch probe 1 is stored3 to 5 – Reserved6 0, 1 Toggled when positive edge position value of touch probe 1 isupdated7 0, 1 Toggled when negative edge position value of touch probe 1 isupdated8 0 Do not use touch probe 21 Use touch probe 29 0 Positive edge position value of touch probe 2 is not stored1 Positive edge position value of touch probe 2 is stored10 0 Negative edge position value of touch probe 2 is not storedwww.comoso.com