Parker HannifinP Series User Guide 2761 Negative edge position value of touch probe 2 is stored11 to 13 – Reserved14 0, 1 Toggled when positive edge position value of touch probe 2 isupdated15 0, 1 Toggled when negative edge position value of touch probe 2 isupdatedTable 109. Touch Probe StatusIn continuous trigger mode, bits 6, 7, 14, 15(store all values for touch probepositive/negative edge) are toggled.To disable bits 1, 2, 9, 10 of touch probe status(0x60B9)(store position values forpositive/negative edge of touch probe 1, 2), first disable bits 4,5,12,13 (use samplingvalues for positive/negative edge of touch probe 1, 2) and then toggle Enable.0x60BA Touch Probe 1 Positive Edge Position Value ALLVariableFormatSetting Range DefaultValue Unit AccessibilityPDOAllocationChangePropertyStoreDINT - - UU RO Yes - NoShow positive edge position value of touch probe 1.0x60BB Touch Probe 1 Negative Edge Position Value ALLVariableFormatSetting Range DefaultValue Unit AccessibilityPDOAllocationChangePropertyStoreDINT - - UU RO Yes - NoShows negative edge value of touch probe 1.0x60BC Touch Probe 2 Positive Edge Position Value ALLVariableFormatSetting Range DefaultValue Unit AccessibilityPDOAllocationChangePropertyStoreDINT - - UU RO Yes - NoShows positive edge value of touch probe 2.0x60BD Touch Probe 2 Negative Edge Position Value ALLVariableFormatSetting Range DefaultValue Unit AccessibilityPDOAllocationChangePropertyStoreDINT - - UU RO Yes - NoShows negative edge value of touch probe 2.www.comoso.com