Parker HannifinP Series User Guide 433.6.2 External Resistor SettingWhen using an external regeneration brake under consideration of the operationenvironment, you should set the brake in the following order.A. External regeneration brake wiring- Connect the external regeneration brake to the B, B+ terminal.- Remove shorts from B, BI terminals (default short at the time of release fromthe factory, 1kW or less)외부회생저항L1L2L3NPOPIB+BBIC1C2BI B+B외부회생저항외부 회생 저항 사용 시 배선 방법B. Regeneration brake setting (0x2009)- Select the external regeneration brake (0x2009=1)- Select this when connecting a regeneration brake with power larger than theinternal regeneration brakeC. Regeneration brake value setting (0x200B)- Set the resistance value of the regeneration brake regeneration brake to[Ω]Unit- The value should be set if the regeneration brake setting (0x2009) is 1.- Default value: 0D. Regeneration brake power setting (0x200C)External regenerationbrake resistorexternal regenerationbrake resistorWiring for external regeneration brake resistorwww.comoso.com