14-8 Frame Relay Module 4.0 User Guide, Rev 01Configuring IPX Filter ApplicationsIPX Filter Applications determine how filters will be used at the interface. To reviewexisting applications, press [C] at the Configure Filter Definitions and ApplicationsMenu (or [A], [A], [E], [F], [C] from the Main Menu). To configure an application, press[D] at the Configure Filter Definitions and Applications Menu. When prompted, enter:l Interface number: 0–63. (The default is 0.) This identifies the virtual interface.l Filter Category: 0 = RIP, 1 = SAP, 2 = Packet, 3 = RIP Router. (The default is 0.)l Direction: i (inbound) or o (outbound). (The default is o.)l Any other requested information, referring to Table 14-6.Figure 14-3 Typical IPX Filter Applications Record[A],[A],[E],[F],[D] from Main MenuUp to 100 filters can be configured, displayed over 9 "pages" (screens).When finished configuring filter definitions and applications, perform an on-lineupdate to make the changes effective immediately. Press [E] at the Filter Definitionsand Applications Configuration Menu. The changes will be sent to the softwarerunning on the RLP(s).IPX Filter A pplications* Interface N umber 2* Filter C ategory 0 RIP* Direction I–I nbou ndA Permit YB Filter A pplication 1 0C Filter A pplication 2 0D Filter A pplication 3 0E Filter A pplication 4 0F Filter A pplication 5 0G Filter A pplication 6 0H Filter A pplication 7 0I Filter A pplication 8 0J Filter A pplication 9 0K Filter A pplication 10 02 Page 2Option: