806f050d-0404ffff Array [ComputerSystemElementName] is in critical condition.Explanation: Drive 4 is part of an RAID array that is in critical condition. Immediate action is required to avoid asystem outage. To identify drives in the critical array all member drives will report this message.May also be shown as 806f050d0404ffff or 0x806f050d0404ffffSeverity: ErrorAlert Category: Critical - Hard Disk driveServiceable: YesCIM Information: Prefix: PLAT and ID: 0174SNMP Trap ID: 5Automatically notify Support: NoUser response:v Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).v Replace the hard disk drive that is indicated by a lit status LED.Related Links:v “Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231v “Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232806f050d-0405ffff Array [ComputerSystemElementName] is in critical condition.Explanation: Drive 5 is part of an RAID array that is in critical condition. Immediate action is required to avoid asystem outage. To identify drives in the critical array all member drives will report this message.May also be shown as 806f050d0405ffff or 0x806f050d0405ffffSeverity: ErrorAlert Category: Critical - Hard Disk driveServiceable: YesCIM Information: Prefix: PLAT and ID: 0174SNMP Trap ID: 5Automatically notify Support: NoUser response:v Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).v Replace the hard disk drive that is indicated by a lit status LED.Related Links:v “Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231v “Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232806f050d-0404ffff • 806f050d-0405ffff1016 System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide