806f010d-0407ffff The [NumericSensorElementName] has been disabled due to a detected fault.Explanation: The drive 7 has been disabled (defunct) due to a fault detected by the controller.May also be shown as 806f010d0407ffff or 0x806f010d0407ffffSeverity: ErrorAlert Category: Critical - Hard Disk driveServiceable: YesCIM Information: Prefix: PLAT and ID: 0164SNMP Trap ID: 5Automatically notify Support: YesUser response:1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.2. Check IBM Support site for firmware updates related to your particular drive.3. Check for any other RAID related errors.4. Replace the drive.Related Links:v “Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231v “Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232806f010d-0408ffff The [NumericSensorElementName] has been disabled due to a detected fault.Explanation: The drive 8 has been disabled (defunct) due to a fault detected by the controller.May also be shown as 806f010d0408ffff or 0x806f010d0408ffffSeverity: ErrorAlert Category: Critical - Hard Disk driveServiceable: YesCIM Information: Prefix: PLAT and ID: 0164SNMP Trap ID: 5Automatically notify Support: YesUser response:1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.2. Check IBM Support site for firmware updates related to your particular drive.3. Check for any other RAID related errors.4. Replace the drive.Related Links:v “Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231v “Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232806f010d-0407ffff • 806f010d-0408ffff700 System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide