806f050d-040effff Array [ComputerSystemElementName] is in critical condition.Explanation: Drive 14 is part of an RAID array that is in critical condition. Immediate action is required to avoid asystem outage. To identify drives in the critical array all member drives will report this message.May also be shown as 806f050d040effff or 0x806f050d040effffSeverity: ErrorAlert Category: Critical - Hard Disk driveServiceable: YesCIM Information: Prefix: PLAT and ID: 0174SNMP Trap ID: 5Automatically notify Support: NoUser response:v Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).v Replace the hard disk drive that is indicated by a lit status LED.Related Links:v “Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231v “Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232806f050d-040fffff Array [ComputerSystemElementName] is in critical condition.Explanation: Drive 15 is part of an RAID array that is in critical condition. Immediate action is required to avoid asystem outage. To identify drives in the critical array all member drives will report this message.May also be shown as 806f050d040fffff or 0x806f050d040fffffSeverity: ErrorAlert Category: Critical - Hard Disk driveServiceable: YesCIM Information: Prefix: PLAT and ID: 0174SNMP Trap ID: 5Automatically notify Support: NoUser response:v Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).v Replace the hard disk drive that is indicated by a lit status LED.Related Links:v “Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231v “Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232806f050d-040effff • 806f050d-040fffffAppendix B. Integrated management module II (IMM2) error messages 1021