80070301-2c01ffff Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.Explanation: The ML2 card has reported a non-recoverable Over temperature condition.May also be shown as 800703012c01ffff or 0x800703012c01ffffSeverity: ErrorAlert Category: Critical - TemperatureServiceable: YesCIM Information: Prefix: PLAT and ID: 0522SNMP Trap ID: 0Automatically notify Support: NoUser response: Complete the following steps until the problem is solved:1. Check the IMM event log for any fan or cooling related issues.2. Make sure that the room temperature is within operating specifications.3. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place andcorrectly installed.4. Make sure that all baffles included with the system are installed.5. Check the heatsink on the ML2 card to ensure that it is free of particulates and dust which would reduce coolingefficiency.6. Remove the heatsink on the ML2 card, check to make sure there is good contact between the heatsink and chip,and then reinstall the heatsink.Related Links:v “Server features and specifications” on page 7v “Removing an ML2 (Ethernet) adapter” on page 254v “Thermal grease” on page 2828007030d-2582ffff Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.Explanation: This message is for the use case when an implementation has detected a Sensor transitioned tonon-recoverable from less severe.May also be shown as 8007030d2582ffff or 0x8007030d2582ffffSeverity: ErrorAlert Category: Critical - OtherServiceable: YesCIM Information: Prefix: PLAT and ID: 0524SNMP Trap ID: 50Automatically notify Support: NoUser response: RAID Vol State :80070301-2c01ffff • 8007030d-2582ffff598 System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide