089-801-000 CPU Stress Test AbortedExplanation: CPU Stress Test Aborted. Internal Program Error.Severity: WarningServiceable: YesRecoverable: NoAutomatically notify Support: NoUser response: Complete the following steps:1. Turn off and restart the system.2. Make sure that the DSA Diagnostic code is at the latest level.3. Run the test again.4. Check system firmware level and upgrade if necessary. The installed firmware level can be found in the DSADiagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for thiscomponent can be found in reference to this system type at the IBM Support website.5. Run the test again.6. If the system has stopped responding, turn off and restart the system and then run the test again.7. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for thenext corrective action.Related Links:v IBM Support Websitev Latest level of DSAv Latest level of BMC/IMM089-802-000 CPU Stress Test AbortedExplanation: CPU Stress Test Aborted. System resource unavailability error.Severity: WarningServiceable: YesRecoverable: NoAutomatically notify Support: NoUser response: Complete the following steps:1. Turn off and restart the system.2. Make sure that the DSA Diagnostic code is at the latest level.3. Run the test again.4. Check system firmware level and upgrade if necessary. The installed firmware level can be found in the DSADiagnostic Event Log within the Firmware/VPD section for this component.5. Run the test again.6. If the system has stopped responding, turn off and restart the system and then run the test again.7. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for thenext corrective action.Related Links:v IBM Support Websitev Latest level of DSAv Latest level of BMC/IMM089-801-000 • 089-802-000320 System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide