806f010d-0409ffff The [NumericSensorElementName] has been disabled due to a detected fault.Explanation: The drive 9 has been disabled (defunct) due to a fault detected by the controller.May also be shown as 806f010d0409ffff or 0x806f010d0409ffffSeverity: ErrorAlert Category: Critical - Hard Disk driveServiceable: YesCIM Information: Prefix: PLAT and ID: 0164SNMP Trap ID: 5Automatically notify Support: YesUser response:1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.2. Check IBM Support site for firmware updates related to your particular drive.3. Check for any other RAID related errors.4. Replace the drive.Related Links:v “Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231v “Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232806f010d-040affff The [NumericSensorElementName] has been disabled due to a detected fault.Explanation: The drive 10 has been disabled (defunct) due to a fault detected by the controller.May also be shown as 806f010d040affff or 0x806f010d040affffSeverity: ErrorAlert Category: Critical - Hard Disk driveServiceable: YesCIM Information: Prefix: PLAT and ID: 0164SNMP Trap ID: 5Automatically notify Support: YesUser response:1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.2. Check IBM Support site for firmware updates related to your particular drive.3. Check for any other RAID related errors.4. Replace the drive.Related Links:v “Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231v “Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232806f010d-0409ffff • 806f010d-040affffAppendix B. Integrated management module II (IMM2) error messages 701