806f020d-2b810815 Failure Predicted on [NumericSensorElementName] for array[ComputerSystemElementName].Explanation: The eXFlash Proxy Service reported a failure predicted (PFA) on the eXFlash DIMM 21 in ComputeBook 1.May also be shown as 806f020d2b810815 or 0x806f020d2b810815Severity: WarningAlert Category: System - Predicted FailureServiceable: YesCIM Information: Prefix: PLAT and ID: 0168SNMP Trap ID: 27Automatically notify Support: YesUser response: At the next maintenance opportunity:1. Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed.2. If the node has recently been installed, moved, serviced, or upgraded, verify that the eXFlash DIMM is properlyseated and visually verify that there is no foreign material in any DIMM connector on that memory channel. Ifeither of these conditions is found, correct and retry with the same eXFlash DIMM. (Note: Event Log may containa recent 00580A4 event denoting detected change in DIMM population that could be related to this problem.)3. Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error.4. If problem persists and there are no other eXFLash DIMMs with the same indication, confirm that the eXFlashDIMM is under warranty before replacement.Related Links:v “Server features and specifications” on page 7v “Removing a DDR3 compute book” on page 283v “Replacing a DDR3 compute book” on page 284v “Removing the DDR3 compute book cover” on page 218v “Replacing the DDR3 compute book cover” on page 220v “Removing a memory module” on page 239v “Replacing a memory module” on page 240v “Flash DIMMs” on page 51806f020d-2b810816 Failure Predicted on [NumericSensorElementName] for array[ComputerSystemElementName].Explanation: The eXFlash Proxy Service reported a failure predicted (PFA) on the eXFlash DIMM 22 in ComputeBook 1.May also be shown as 806f020d2b810816 or 0x806f020d2b810816Severity: WarningAlert Category: System - Predicted FailureServiceable: YesCIM Information: Prefix: PLAT and ID: 0168SNMP Trap ID: 27Automatically notify Support: YesUser response: At the next maintenance opportunity:1. Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed.2. If the node has recently been installed, moved, serviced, or upgraded, verify that the eXFlash DIMM is properlyseated and visually verify that there is no foreign material in any DIMM connector on that memory channel. If806f020d-2b810815 • 806f020d-2b810816800 System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide