80040104-1d02ffff Sensor [SensorElementName] is asserting predictive failure.Explanation: IMM predicted Fan 2 needs to be replaced to prevent a cooling failure.May also be shown as 800401041d02ffff or 0x800401041d02ffffSeverity: WarningAlert Category: System - Predicted FailureServiceable: YesCIM Information: Prefix: PLAT and ID: 0510SNMP Trap ID: 27Automatically notify Support: NoUser response: Replace fan as soon as possible.Related Links:v “Removing a hot-swap fan assembly” on page 251v “Replacing a hot-swap fan assembly” on page 25280040104-1d03ffff Sensor [SensorElementName] is asserting predictive failure.Explanation: IMM predicted Fan 3 needs to be replaced to prevent a cooling failure.May also be shown as 800401041d03ffff or 0x800401041d03ffffSeverity: WarningAlert Category: System - Predicted FailureServiceable: YesCIM Information: Prefix: PLAT and ID: 0510SNMP Trap ID: 27Automatically notify Support: NoUser response: Replace fan as soon as possible.Related Links:v “Removing a hot-swap fan assembly” on page 251v “Replacing a hot-swap fan assembly” on page 25280040104-1d04ffff Sensor [SensorElementName] is asserting predictive failure.Explanation: IMM predicted Fan 4 needs to be replaced to prevent a cooling failure.May also be shown as 800401041d04ffff or 0x800401041d04ffffSeverity: WarningAlert Category: System - Predicted FailureServiceable: YesCIM Information: Prefix: PLAT and ID: 0510SNMP Trap ID: 27Automatically notify Support: NoUser response: Replace fan as soon as possible.Related Links:v “Removing a hot-swap fan assembly” on page 251v “Replacing a hot-swap fan assembly” on page 25280040104-1d02ffff • 80040104-1d04ffffAppendix B. Integrated management module II (IMM2) error messages 541