806f0207-2583ffff [ProcessorElementName] has Failed with FRB1/BIST condition.Explanation: IMM has reported a microprocessor Failed - FRB1/BIST condition.May also be shown as 806f02072583ffff or 0x806f02072583ffffSeverity: ErrorAlert Category: Critical - CPUServiceable: YesCIM Information: Prefix: PLAT and ID: 0044SNMP Trap ID: 40Automatically notify Support: YesUser response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the loggedIMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Centerfor the appropriate user response.Related Links:v “Finding the UEFI (POST) error code” on page 1666806f020d-0400ffff Failure Predicted on [NumericSensorElementName] for array [ComputerSystemElementName].Explanation: Failure predicted (PFA) on the hard drive 0.May also be shown as 806f020d0400ffff or 0x806f020d0400ffffSeverity: WarningAlert Category: System - Predicted FailureServiceable: YesCIM Information: Prefix: PLAT and ID: 0168SNMP Trap ID: 27Automatically notify Support: YesUser response: Replace the hard disk drive at the next maintenance period.Related Links:v “Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231v “Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232806f020d-0401ffff Failure Predicted on [NumericSensorElementName] for array [ComputerSystemElementName].Explanation: Failure predicted (PFA) on the hard drive 1.May also be shown as 806f020d0401ffff or 0x806f020d0401ffffSeverity: WarningAlert Category: System - Predicted FailureServiceable: YesCIM Information: Prefix: PLAT and ID: 0168SNMP Trap ID: 27Automatically notify Support: YesUser response: Replace the hard disk drive at the next maintenance period.Related Links:v “Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231v “Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232806f0207-2583ffff • 806f020d-0401ffffAppendix B. Integrated management module II (IMM2) error messages 781