v “Removing a memory module” on page 239v “Replacing a memory module” on page 240v “Flash DIMMs” on page 51806f010d-2b830012 The [NumericSensorElementName] has been disabled due to a detected fault.Explanation: The eXFlash Proxy Service detected a fault on the eXFlash DIMM 18 in Compute Book 3.May also be shown as 806f010d2b830012 or 0x806f010d2b830012Severity: ErrorAlert Category: Critical - Hard Disk driveServiceable: YesCIM Information: Prefix: PLAT and ID: 0164SNMP Trap ID: 5Automatically notify Support: YesUser response:1. Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed.2. Reinstall your eXFlash IPMI Proxy Service.3. Perform a full AC power cycle on the system.4. If the node has recently been installed, moved, serviced, or upgraded, verify that the eXFlash DIMM is properlyseated and visually verify that there is no foreign material in any DIMM connector on that memory channel. Ifeither of these conditions is found, correct and retry with the same eXFlash DIMM. (Note: Event Log may containa recent 00580A4 event denoting detected change in DIMM population that could be related to this problem.)5. Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error.6. If problem persists and there are no other eXFLash DIMMs with the same indication, confirm that the eXFlashDIMM is under warranty before replacement.7. Replace compute book.8. (Trained Service technician only) Replace affected Processor.Related Links:v “Server features and specifications” on page 7v “Removing a DDR3 compute book” on page 283v “Replacing a DDR3 compute book” on page 284v “Removing the DDR3 compute book cover” on page 218v “Replacing the DDR3 compute book cover” on page 220v “Removing a memory module” on page 239v “Replacing a memory module” on page 240v “Flash DIMMs” on page 51806f010d-2b830012Appendix B. Integrated management module II (IMM2) error messages 753