806f020d-040bffff Failure Predicted on [NumericSensorElementName] for array [ComputerSystemElementName].Explanation: Failure predicted (PFA) on the hard drive 11.May also be shown as 806f020d040bffff or 0x806f020d040bffffSeverity: WarningAlert Category: System - Predicted FailureServiceable: YesCIM Information: Prefix: PLAT and ID: 0168SNMP Trap ID: 27Automatically notify Support: YesUser response: Replace the hard disk drive at the next maintenance period.Related Links:v “Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231v “Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232806f020d-040cffff Failure Predicted on [NumericSensorElementName] for array [ComputerSystemElementName].Explanation: Failure predicted (PFA) on the hard drive 12.May also be shown as 806f020d040cffff or 0x806f020d040cffffSeverity: WarningAlert Category: System - Predicted FailureServiceable: YesCIM Information: Prefix: PLAT and ID: 0168SNMP Trap ID: 27Automatically notify Support: YesUser response: Replace the hard disk drive at the next maintenance period.Related Links:v “Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231v “Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232806f020d-040dffff Failure Predicted on [NumericSensorElementName] for array [ComputerSystemElementName].Explanation: Failure predicted (PFA) on the hard drive 13.May also be shown as 806f020d040dffff or 0x806f020d040dffffSeverity: WarningAlert Category: System - Predicted FailureServiceable: YesCIM Information: Prefix: PLAT and ID: 0168SNMP Trap ID: 27Automatically notify Support: YesUser response: Replace the hard disk drive at the next maintenance period.Related Links:v “Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231v “Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232806f020d-040bffff • 806f020d-040dffffAppendix B. Integrated management module II (IMM2) error messages 785