806f011b-1f01ffff The connector [PhysicalConnectorElementName] has encountered a configuration error.Explanation: IMM has detected the Storage I/O Book has a cable / interconnect problem.May also be shown as 806f011b1f01ffff or 0x806f011b1f01ffffSeverity: ErrorAlert Category: Critical - OtherServiceable: YesCIM Information: Prefix: PLAT and ID: 0266SNMP Trap ID: 50Automatically notify Support: YesUser response: Storage Book: Card or Drive backplane cable FP LCD Cable: Front Panel LCD cable1. Remove the Storage Book2. Check for missing or loose cables in the Storage Book.3. Check connector for damege or debris.Related Links:v “Removing the storage book” on page 266806f0123-2101ffff Reboot of system [ComputerSystemElementName] initiated by [WatchdogElementName].Explanation: The IPMI Watchdog Timer has expired. A reboot of the system was initiated.May also be shown as 806f01232101ffff or 0x806f01232101ffffSeverity: InfoAlert Category: System - OtherServiceable: NoCIM Information: Prefix: PLAT and ID: 0370SNMP Trap ID:Automatically notify Support: NoUser response: Information only; no action is required.806f0125-2c05ffff [ManagedElementName] detected as absent.Explanation: IMM has detected that the Storage Book is absent.May also be shown as 806f01252c05ffff or 0x806f01252c05ffffSeverity: InfoAlert Category: System - OtherServiceable: noCIM Information: Prefix: PLAT and ID: 0392SNMP Trap ID:Automatically notify Support: noUser response:1. If the Storage Book was intentionally removed, no action required.2. Make sure that the Storage Book is properly seated.3. If Storage Book is properly seated, replace the Storage Book.Related Links:v “Removing the storage book board assembly” on page 268806f011b-1f01ffff • 806f0125-2c05ffff778 System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide