Table 29. Population sequence for the supported power supply configurations for each4-socket nodePower supply configuration Notes:1 power supply The power supply should be installed in bay3. This configuration does not supportpower supply redundancy. A power supplyfiller must be installed in bays 1, 2, and 4.2 power supplies The power supplies should be installed inbays 2 and 3 with each supply on separatepower feeds for feed redundancy. Bothpower supplies must be the same type (thatis, the same wattage, ac power supplies, ordc power supplies). A power supply fillermust be installed in bays 1 and 4.4 power supplies Power supplies 1, 2, 3, and 4 must be thesame input type (that is, all ac powersupplies or all dc power supplies).v Four 750-watt -48 volt dc power supplies is the only 750-watt -48 volt dc powersupply configuration that the server supports (for each 4-socket node).v The following table lists the supported ac power supply configurations at both220 V ac and 110 V ac. These configurations apply for each 4-socket node of the8-socket server:Table 30. Supported ac power supply configurations at both 220 V ac and 110 V ac for each4-socket nodeNumber of power supplies Power supply wattageOne 900-wattOne 1400-wattTwo 900-wattTwo 1400-wattFour Two 900-watt and two 1400-wattFour 900-wattFour 1400-wattv If you mix 900-watt and 1400-watt power supplies in the server, the powersupplies must be installed as listed in the table below. These configurationsapply for each 4-socket node of the 8-socket server.Table 31. Support configurations when mixing 900-watt and 1400-watt ac power supplies foreach 4-socket node.Note: If you are using two power input feeds, connect power supplies 1 and 3 to input feedA and power supplies 2 and 4 to input feed B.Power supply bay number Power supply wattageBays 1 and 4 900-wattBays 2 and 3 1400-wattORBays 1 and 4 1400-wattBays 2 and 3 900-wattChapter 2. Installing optional devices 105