806f060d-0402ffff Array [ComputerSystemElementName] has failed.Explanation: Drive 2 is part of an RAID array that is in the failed condition. To identify drives in the failed array allmember drives will report this message.May also be shown as 806f060d0402ffff or 0x806f060d0402ffffSeverity: ErrorAlert Category: Critical - Hard Disk driveServiceable: YesCIM Information: Prefix: PLAT and ID: 0176SNMP Trap ID: 5Automatically notify Support: YesUser response:v Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).v Replace the hard disk drives that are indicated by a lit status LED.v Recreate the array.v Restore data from backup.Related Links:v “Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231v “Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232806f060d-0403ffff Array [ComputerSystemElementName] has failed.Explanation: Drive 3 is part of an RAID array that is in the failed condition. To identify drives in the failed array allmember drives will report this message.May also be shown as 806f060d0403ffff or 0x806f060d0403ffffSeverity: ErrorAlert Category: Critical - Hard Disk driveServiceable: YesCIM Information: Prefix: PLAT and ID: 0176SNMP Trap ID: 5Automatically notify Support: YesUser response:v Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).v Replace the hard disk drives that are indicated by a lit status LED.v Recreate the array.v Restore data from backup.Related Links:v “Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231v “Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232806f060d-0402ffff • 806f060d-0403ffff1026 System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide