80080128-2101ffff Device [LogicalDeviceElementName] has been added.Explanation: IMM has detected low security jumper has been added.May also be shown as 800801282101ffff or 0x800801282101ffffSeverity: InfoAlert Category: System - OtherServiceable: NoCIM Information: Prefix: PLAT and ID: 0536SNMP Trap ID:Automatically notify Support: NoUser response: Information only; no action is required.800b0008-1381ffff Redundancy [RedundancySetElementName] has been restored.Explanation: Power Supply Redundancy has been Restored.May also be shown as 800b00081381ffff or 0x800b00081381ffffSeverity: InfoAlert Category: Warning - Redundant Power SupplyServiceable: NoCIM Information: Prefix: PLAT and ID: 0561SNMP Trap ID: 10Automatically notify Support: NoUser response: Information only; no action is required.800b0108-1381ffff Redundancy Lost for [RedundancySetElementName] has asserted.Explanation: Power Supply Redundancy has been lost.May also be shown as 800b01081381ffff or 0x800b01081381ffffSeverity: ErrorAlert Category: Critical - Redundant Power SupplyServiceable: YesCIM Information: Prefix: PLAT and ID: 0802SNMP Trap ID: 9Automatically notify Support: NoUser response:1. Power Unit: Check if Power Supply is missing, unplugged.2. Check the power supply LEDs, see "Power-supply LEDs"3. Replace the affected power supply.Related Links:v “Solving power problems” on page 197v “Installing power supplies” on page 104v “Removing a 1400-watt or 900-watt hot-swap power supply” on page 247v “Removing a 750-watt -48 volt to -60 volt dc power supply” on page 287v “Replacing a 1400-watt or 900-watt hot-swap power supply” on page 248v “Replacing a 750-watt -48 volt to -60 volt dc power supply” on page 28980080128-2101ffff • 800b0108-1381ffff608 System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide