Parameter Declaration Data type DescriptionACLBlock INPUT BLOCK Data block with the access codes.Ä Chap. 7.3.3‘UDT 4 - ACL - Data structure for FB 48’ page 109Access1 OUTPUT BOOL Output 1, can be controlled as pulse or static.Access2 OUTPUT BOOL Output 2, can be controlled as pulse or static.Access3 OUTPUT BOOL Output 3, can be controlled as pulse or static.Access4 OUTPUT BOOL Output 4, can be controlled as pulse or static.Access5 OUTPUT BOOL Output 5, can be controlled as pulse or static.Access6 OUTPUT BOOL Output 6, can be controlled as pulse or static.Error OUTPUT BOOL If the access code does not exist in the datablock, the output Error is set for the duration Time-Error.CentralLocked OUTPUT BOOL n Access– TRUE: locked - access not possible– FALSE: not locked - access possibleDefault: TRUETimePulse CONSTANT Time Time for the pulse duration at an output.Default: 3sTimeError CONSTANT Time Time for the duration of the error signal.Default: 500ms7.3.2 UDT 3 - ACLREC - Data structure for FB 48Address Name Type Start value Comment0.0 STRUCT+0.0 Code STRING[16] ' ' Byte 0 ... 17: Access codeS7String with max. 16 ASCII characters foraccess code+18.0 EnableOutput1 BOOL FALSE Byte 18: Signal for the outputs to be controlledTRUE: activate output,FALSE: deactivate output+18.1 EnableOutput2 BOOL FALSE+18.2 EnableOutput3 BOOL FALSE+18.3 EnableOutput4 BOOL FALSE+18.4 EnableOutput5 BOOL FALSE+18.5 EnableOutput6 BOOL FALSE+18.6 EnableRes7 BOOL FALSE+18.7 EnableRes8 BOOL FALSEDescriptionVIPA SPEED7Building ControlAccess Control > UDT 3 - ACLREC - Data structure for FB 48HB00 | OPL_SP7 | Operation list | en | 18-30108