13.8.3 Modify the project in Movicon1. Open via ‘Resources > SimpleMotion >Screens’ ‘Screen1’ .2. Navigate in ‘Browse Folders’ at ‘vipa simple motion control ...’ and drag & dropfrom the ‘Library view’ the template to the ‘Screen1’ , which matches the resolutionof your panel.ð The initialization dialog opens3. Specify a name for the axis. Allowed characters: A-Z, a-z, 0-9, space and the sepa-rators "_" and "-"Specify the instance DB number that you use in your PLC program.Specify the station name. This must match the ‘Station Name’ from ‘StationProperties’ of the ‘S7 TCP’ communication settings. Allowed characters: A-Z, a-z,0-9, space and the separators "_" and "-"ð With [OK] all variables as well as their structures are generated and theaddresses are set to the specified destination address.4. Place the template and adjust its size.Variables are created for each template under the correspondingname. When deleting the template, the corresponding variablesmust be deleted again. You can select these at ‘Resources >SimpleMotion > Real Time DB > Variables’ . Delete these togetherwith the higher-level directory. If no further templates access the‘Structure Prototypes’ for the Axis control, these must also bedeleted.Configuring the screenVIPA SPEED7 Motion control - Simple Motion Control LibraryControlling the drive via HMI > Modify the project in MoviconHB00 | OPL_SP7 | Operation list | en | 18-30 619