1. Select ‘Project è Compile all’ and transfer the project into your CPU. You can findmore information on the transfer of your project in the online help of the SPEED7Studio.ð You can take your application into operation now.CAUTION!Please always observe the safety instructions for your drive,especially during commissioning!2. Bring your CPU into RUN and turn on your drive.ð The FB 885 - VMC_AxisControlV1000PWM is executed cyclically.3. As soon as AxisReady = TRUE, you can use AxisEnable to enable the drive.4. You now have the possibility to control your drive via its parameters and to check itsstatus.Ä Chap. 13.4.7.1 ‘FB 885 - VMC_AxisControlV1000_PWM - Axis controlover PWM’ page 44913.4.5 Usage in Siemens SIMATIC Manager13.4.5.1 Preconditionn Please use for configuration the Siemens SIMATIC Manager V 5.5 SP2 and up.n The configuration of the VIPA CPU with PWM functionality happens in the SiemensSIMATIC Manager by means of a virtual PROFINET IO device.n The PROFINET IO Device is to be installed in the hardware catalog by means of aGSDML.The installation of the PROFINET VIPA IO device happens in the hardware catalog withthe following approach:1. Go to the service area of www.vipa.com.2. Download the configuration file for your CPU from the download area via‘Config files è PROFINET’.3. Extract the file into your working directory.4. Start the Siemens hardware configurator.5. Close all the projects.6. Select ‘Options è Install new GSD file’.7. Navigate to your working directory and install the according GSDML file.ð After the installation according PROFINET IO device can be found at‘PROFINET IO è Additional field devices è I/O è VIPA ...’.Sequence of operationsOverviewInstalling the VIPA IOdeviceVIPA SPEED7Motion control - Simple Motion Control LibraryUsage inverter drive via PWM > Usage in Siemens SIMATIC ManagerHB00 | OPL_SP7 | Operation list | en | 18-30438