Configuring the System − Getting StartedPage 196. Choose the language:From this point on, the display operates in the selected language. If you want tochange the language later, use Installer menu – System Options – Updates –Language.7. Choose the country version you want to use:8. Select the wiring type to use for wired zones:Further information about zone wiring types is given on page 14.Note: If you are using an ADP-10CC board (to provide ten on-board 4-wire CC zonesinstead of ten FSL zones), select 2-wire FSL 2k2/4k7 as the wiring type.Note: You can change this setting later using Installer menu – System Options.9. If you selected the UK as the country version, specify the alarm confirmation mode:Please refer to page 52 if you need information about confirmation modes. You canchange this setting later using Installer menu – System Options – Confirmation –Confirmation Mode.10. User codes (e.g. to set or unset the system) can be four or six digits long. Select therequired length:Note: You can change this setting later using Installer menu – System Options –Restore Defaults – Staged Defaults – Users.11. Specify an installer code:When prompted, confirm the code. DO NOT FORGET THIS CODE!12. Specify a code for the default master user:When prompted, confirm the code. DO NOT FORGET THIS CODE!13. You will see one of the following: If the lid of the control unit is closed, you will see the standby screen. Forexample:You can change the wiring type by pressing one or moretimes. Press to continue.Press if you want to select six-digit user codes. Press tocontinue. (The Follow Panel Grade option sets user codes to thedefault length for the panel grade, which for i-on10 is four digits.)Use the numeric keys to specify the code.You can change the country by pressing one or more times.Press to continue.You can change the language by pressing one or more times.Press to continue.You can change the confirmation mode by pressing one or moretimes. Press to continue.