Installer Menu MapPage 71Strobe on Set OffStrobe on Unset Off4 System OptionsUser Options User Access HUA keys active NoQuick set NoQuick omit NoUser code reqd YesDuress Enable NoTerminated Set Yes Used for KEY-EP.Tamper Omit NoSilence Alerts User CodeUser Reset Zone alarms Yes Available only if Confirmation Mode is”Basic”.Zone tampers YesSystem tampers YesCode tampers YesKeypad Text Model nameRestoreDefaultsStaged defaults UsersUser 01ZonesOutputsSetting InfoSystem OptionsCommunicationsFactory defaultsInstallerOptionsInstaller Name “Installer”Installer Code Installer configuredInstaller Timeout 60 minutesService Date 01/01/1900Service Banner DisabledConfirmation Confirmation Mode DD243 These options are available only whenthe country version is the UK. For allother countries, Basic is used.BS8243 Default for UK systemsBasicConfirmation Time 30 minutes Available for BS8243 or DD243.Entry Alarm Delay YesAfter Entry 1 zones Available for BS8243 or DD243.Default changes to 2 zones whenConfirmation Mode = DD243.Entry Keypad Lock Off Available for BS8243 or DD243.Sounder on UnconfirmedSiren on UnconfirmedUnconfirmed reset User Available for BS8243 or DD243.Confirmed reset Installer Available for BS8243 or DD243.HUA Response AudibleHUA Confirm Time 8 hours Available for BS8243 only.Tamp as Tamp-Only Enabled Available for BS8243 only.Abort Time 120 secondsAuto Rearm Never Available only when ConfirmationMode is “Basic”.Hardware Panel NameWired Zone Type Panel Zones 2 Wire FSL 2k2/4k7Panel Loudspeaker Volume 4Mains Fail Delay 0 minutesLinked Zone Time 10 secondsPanel Tamper Return CCReset Codes Pins EnabledDate andTimeSet Date & TimeUpdates Language