Installer Menu MapPage 70Delete KeypadEnable Keypad Yes (all keypads enabled)Replace Keypad2 OutputsWired outputs(Panel EDIT outputNameType For outputs 1 and 3, the default"Type" is "Siren". For output 2, thedefault "Type" is "Strobe".Polarity NormalLatched No For User-Defined output type.Pulsed No Not available for dedicated siren andstrobe outputs.Delay 0 seconds Available when Pulsed set to “Yes”.On Time 1 secondZones None Available only for Zone Follow andZone Alarm output types.Plug-byoutputsEDIT PLUG-BYO/P1...NameType O/P1: Fire AlarmO/P2: Hold Up AlarmO/P3: Burglar AlarmO/P4: Open / CloseO/P5: Zone Omit (System)O/P6: TamperO/P7: Confirmed AlarmO/P8: General FaultPolarity NormalLatched No For User-Defined output type.Pulsed No Not available for dedicated siren andstrobe outputs.Delay 0 seconds Available when Pulsed set to “Yes”.On Time 1 secondZones None Available only for Zone Follow andZone Alarm output types.3 Setting optionsFull Set Name “Full Set”Exit Mode Timed SetSettle Time 15 seconds Available only if Exit Mode is “FinalDoor Set”.Confirm Set On Available only if Exit Mode is “SilentSet”.Exit Time 40 seconds Available only if Exit Mode is “TimedSet” or “Silent Set”.Entry Time 40 secondsExtended Entry Time 40 secondsSiren Delay 0Siren Time 15 minutesStrobe on Set OffStrobe on Unset OffPart SetB/C/D(available only if azone has a Part Setattribute)Name “Part Set B/C/D”Exit Mode Instant SetSettle Time 15 seconds Available only if Exit Mode is “FinalDoor Set”.Confirm Set On Available only if Exit Mode is “SilentSet”.Exit Time 40 seconds Available only if Exit Mode is “TimedSet” or “Silent Set”.Entry Time 40 secondsExtended Entry Time 40 secondsAlarm Response SirenSiren Delay 0Siren Time 15 minutesPt.set Final Exit Final exitPt.set Entry Route Entry Route