Outputs MenuPage 39Confirmed Alarm (07)Active when there is a confirmed alarm. Deactivates when the system is reset. Theoperation of this output type depends on the option selected in System Options –Confirmation – Confirmation Mode (see page 52):A/C Fail (12)Active when mains power is absent. The action of this output depends on the valueprogrammed in System Options – Hardware – Mains Fail Delay (see page 57).Battery Fault (13)Active when the control unit detects a fault with its backup battery. The control unitdeactivates the output when it detects a good battery.Tamper (16)Active when the control unit detects a tamper at the control unit (lid or back), wiredkeypad, detector, or when there is an activation of a zone of type Tamper.The control unit deactivates the output when tamper is reset.Zone Omit (Setting) (17)Active when the user omits a zone while setting the system. The output deactivateswhen the control unit restores the zone.Zone Omit (System) (18)In the event of an unconfirmed alarm, the system will rearm itself when theconfirmation timer expires. If the zone that caused the unconfirmed alarm is stillactive at the time of the rearm, the control unit will omit that zone and activate theoutput. The control unit will restore the zone and output when a user or engineerresets the system.General Fault (19)Active when there is any event that causes an alert indication. This includes: AC Fail,Battery Fault and Tamper.Note that a General Fault output will trigger within a few seconds of an AC Fail, andis NOT affected by the Mains Fail Delay setting.Siren (21)Active when the control unit starts a full alarm, a hold up alarm or a fire alarm (thesiren has a distinctive tone during a fire alarm). The control unit deactivates thisoutput at the end of the siren time. See page 46 to choose the siren duration.Strobe (22)Active when either of the following occurs:a) The control unit starts a full alarm, hold-up alarm or fire alarm. The output remainsactive until the user disarms the system.b) Setting or unsetting, if you have selected “strobe on set” and/or “strobe on unset”(see page 46).Entry Exit Follow (23)Active when the entry or exit time starts and deactivates at the end of the entry/exittime, or if the entry/exit time is terminated. The output can be used for a separateentry/exit buzzer. Note that the output does not operate if the exit mode is silent setor instant set.Armed (24)Active when the system is full or part set.